The chimney must extend at least 3 above the highest point where it passes through a roof.
Residential chimney height above roof.
For most small structures like small cabins and tiny homes the tallest part of the structure is within 10 of the chimney.
If the pitch of the roof is 38 degrees or greater the termination point of the flue or chimney will need to be 2300mm horizontally from the roof line and roofing material.
Specifications aren t there to merely cause you problems.
They intend to make sure that the chimney draws properly and that a fire hazard does not occur.
The top of the chimney should be at least 3 ft 0 92 m above the roof surface.
The 10 foot rule explains the clearance you need.
The chimney opening above the roof of a sticks and bricks house should be 3 feet above the roof line or 2 feet above any part of the building within 10 whichever is higher.
Chimneys shall extend not less than 2 feet 610 mm higher than any portion of a building within 10 feet 3048 mm but shall be not less than 3 feet 914 mm above the highest point where the chimney passes through the roof.
Degrees the height of flue or chimney stack will need to be at least 1800mm above the roof when not close to the ridge.
If your chimney is exposed and is greater than 5 tall a roof brace kit is required to keep it supported.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
For gas vents or a type l vent this distance above the roof surface must be at least 2 ft 0 61m.
And at least 2 higher than any portion of a building within 10.
If you draw a horizontal line 10 the chimney will be 6 from the shingles and you need to add 2 from that mark therefore you will have a total of 8 of chimney above your shingles.
This specification makes sure steep roof slopes are cleared.
Most wood stove and factory built fireplace manufacturers and local building codes will require that the chimney must extend at least 2 feet above any portion of any structure within 10 feet measured horizontally and must extend at least 3 feet above the highest point of its roof penetration.
Both above the flat roof and 2 feet above the point at which a horizontal line from the chimney would touch the highest portion of the nearest roof.